Advanced Configuration
Global Settings
Click the settings icon
Global Settings.
There are three settings for sensitivity which control the
threshold for detection (as well as false alarms): Low,
Medium, and High. When set to low, the analytics will
detect fewer objects (also fewer false alarms) than when
set to high.
Set Show Regions to Yes to show any detection areas
as black boxes and tripwires as black lines in the video.
The tracking display options are: All Boxes, Classified
Boxes, Show Triggered, and No Boxes. If any of
options to show boxes is selected, a check box enables
a tracking line with each detection box.
All Boxes—every detected motion is shown with a
box around it
Classified Boxes—detected motion classified as
vehicle, human, or object of interest is shown with a
box around it labeled "H", "V", or "O".
Show Triggered—detected motion that triggers an alarm is shown with a box around it.
No Boxes—detected motion is not shown with a box
Lines—show the track of an object based on its position from prior frames. This helps to visually
represent speed and direction of motion (only available if All or Classified Boxes is selected).
Tamper Sensitivity—set the percentage of pixels that are detected as unchanged when
compared to stored history video frames to trigger an alarm.