Electrical Specifications; Environmental Specifications - Sun Oracle Netra SPARC T5-1B Installation Manual

Server module
Table of Contents

Advertisement

Related Information
"Server Module Overview" on page 2

Electrical Specifications

Description
Voltage
Voltage (auxiliary)
Maximum operating power
For information on power specifications, use the power calculator at:
http://www.oracle.com/us/products/servers-storage/sun-power-calc
ulators
Also refer to information about configuring server module power usage in the Netra
SPARC T5-1B Server Module Product Notes.
Related Information
"Powering On the Server Module for the First Time" on page 27

Environmental Specifications

Description
Temperature
Relative
humidity
8
Netra SPARC T5-1B Server Module Installation Guide • October 2013
Operating
5˚C to 40˚C (41˚F to 104˚F)
Short-term: -5˚C to 55˚C (23˚F to 131˚F)
5% to 85%, non-condensing
Short-term: 5% to 90%,
non-condensing, but not to exceed
0.024 kg water/kg dry air (0.053 lb.
water/2.205 lbs. dry air)
Value
Notes
12V
From chassis backplane.
3.3V
From chassis backplane.
740 W
Estimated.
Nonoperating
Up to 93%, noncondensing, 40˚C
(104˚F)
Up to 93%, noncondensing, 40˚C
(104˚F)