Hitachi SJ100 Series Instruction Manual page 31

Hide thumbs Also See for SJ100 Series:
Table of Contents

Advertisement

Item
SJ100 inverters, 400V models
Applicable motor size *2
Rated capacity (460V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Starting torque *6
Dynamic braking
without resistor,
from 50/60 Hz
approx. % torque,
short time stop *7
with resistor
DC braking
Weight
kg / lb
Footnotes for the preceding tables and the table on the following page:
*1: The protection method conforms to JEM 1030.
*2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). To use other
motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the
rated output current of the inverter.
*3: The output voltage decreases as the main supply voltage decreases (except for use of the
AVR function). In any case, the output voltage cannot exceed the input power supply
voltage.
*4: To operate the motor beyond 50/60 Hz, consult the motor manufacturer about the maximum
allowable rotation speed.
*5: SLV selected, set carrier frequency more than 2.1 kHz.
*6: At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor (when selecting
high starting torque flux vector control).
*7: The braking torque via capacitive feedback is the average deceleration torque at the shortest
deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking
torque. And, the average deceleration torque varies with motor loss. This value decreases
when operating beyond 50 Hz. If a large regenerative torque is required, the optional regen-
erative braking resistor should be used.
*8: The frequency command is the maximum frequency at 9.8V for input voltage 0 to 10 VDC,
or at 19.6 mA for input current 4 to 20 mA. If this characteristic is not convenient for your
application, contact your Hitachi sales representative.
*9: If operating the inverter at 40 to 50
output current by 80%, and remove the top housing cover. Note that removing the top cover
will nullify the NEMA rating for the inverter housing.
*10:The storage temperature refers to the short-term temperature during transport.
*11:Conforms to the test method specified in JIS C0911 (1984). For the model types excluded in
the standard specifications, contact your Hitachi sales representative.
*12:The input voltage of xxLFU is 230V.
400V Class Specifications
004HFE
007HFE
015HFE
004HFU
007HFU
015HFU
kW
0.4
0.75
1.5
HP
1/2
1
2
1.1
1.9
2.9
3-phase: 380 to 415/400 to 460V ±10%, 50/60 Hz ±5%
2.0
3.3
5.0
3-phase: 380 to 415/400 to 460V (corresponding to input voltage)
1.5
2.5
3.8
200% or more
100%: ≤ 50Hz
50%: ≤ 60Hz
150%
Variable operating frequency, time, and braking force
1.3/2.9
1.7/3.7
1.7/3.7
°
C, reduce the carrier frequency to 2.1 kHz, derate the
SJ100 Inverter
022HFE
030HFE
040HFE
055HFE
022HFU
040HFU
055HFU
2.2
3.0
4.0
3
4
5
4.2
6.2
6.6
7.0
10.0
11.0
5.5
7.8
8.6
180% or more
40%: ≤ 50Hz
20%: ≤ 60Hz
100%
2.8/6.2
2.8/6.2
2.8/6.2
5.5/12.1
1–5
075HFE
075HFU
5.5
7.5
7.5
10
10.3
12.7
16.5
20.0
13
16
20%: ≤ 50Hz
20%: ≤ 60Hz
80%
5.7/12.5