MODBUS REGISTER MAP
Hex
Decimal
0FA6 - 0FA6 4007 - 4007 Phase A Current 1st
0FA7 - 0FA7 4008 - 4008 Phase A Current 2nd
0FA8 - 0FA8 4009 - 4009 Phase A Current 3rd
0FA9 - 0FA9 4010 - 4010 Phase A Current 4th
0FAA - 0FAA 4011 - 4011 Phase A Current 5th
0FAB - 0FAB 4012 - 4012 Phase A Current 6th
0FAC - 0FAC 4013 - 4013 Phase A Current 7th
0FAD - 0FAD 4014 - 4014 Phase A Voltage 0th
0FAE - 0FAE 4015 - 4015 Phase A Voltage 1st
0FAF - 0FAF 4016 - 4016 Phase A Voltage 2nd
0FB0 - 0FB0 4017 - 4017 Phase A Voltage 3rd
0FB1 - 0FB8 4018 - 4025 Phase B Current
0FB9 - 0FBC 4026 - 4029 Phase B Voltage
0FBD - 0FC4 4030 - 4037 Phase C Current
0FC5 - 0FC8 4038 - 4041 Phase C Voltage
14
Phase Angle Block
1003 - 1003 4100
- 4100 Phase A Current
1004 - 1004 4101 - 4101 Phase B Current
1005 - 1005 4102 - 4102 Phase C Current
1006 - 1006 4103 - 4103 Angle, Volts A-B
1007 - 1007 4104 - 4104 Angle, Volts B-C
1008 - 1008 4105 - 4105 Angle, Volts C-A
Status Block
1387 - 1387 5000
- 5000 Meter Status
1388 - 1388 5001 - 5001 Limits Status
1389 - 138A 5002 - 5003 Time Since Reset
9
Resets Block
4E1F - 4E1F 20000 - 20000 Reset Max/Min Blocks UINT16 password
B–8
Table Appendix B –1: Modbus Register Map (Sheet 4 of 9)
1
Format
Description
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
UINT16 0 to 65535
harmonic magnitude
same as Phase A Current 0th to 7th harmonic magnitudes
same as Phase A Voltage 0th to 3rd harmonic magnitudes
same as Phase A Current 0th to 7th harmonic magnitudes
same as Phase A Voltage 0th to 3rd harmonic magnitudes
SINT16 -1800 to +1800
SINT16 -1800 to +1800
SINT16 -1800 to +1800
SINT16 -1800 to +1800
SINT16 -1800 to +1800
SINT16 -1800 to +1800
UINT16 bit-mapped
7
UINT16 bit-mapped
UINT32 0 to 4294967294
Commands Section
APPENDIX B: MODBUS MAPPING FOR EPM6000
Units or
6
Range
Resolution
none
none
none
none
none
none
none
none
none
none
none
0.1 degree
0.1 degree
0.1 degree
0.1 degree
0.1 degree
0.1 degree
--exnpch
ssssssss
87654321
87654321
4 msec
4
5
EPM6000 MULTI-FUNCTION POWER METERING SYSTEM – USER GUIDE
Comments
1
1
1
1
1
1
1
1
1
1
1
8
4
8
4
Block Size:
42
read-only
1
1
1
1
1
1
Block Size:
6
read-only
exnpch = EEPROM block OK
1
flags (e=energy, x=max,
n=min, p=programmable
settings, c=calibration,
h=header),
ssssssss = state (1=Run,
2=Limp, 10=Prog Set
Update via buttons,
11=Prog Set Update via
IrDA, 12=Prog Set Update
via COM2)
high byte is setpt 1, 0=in,
1
1=out
low byte is setpt 2, 0=in,
1=out
wraps around after max
2
count
Block Size:
4
write-only
1
#
R
e
g