8. Remove the 5 screws securing the liquid cooling panel. Four of these screens are on the panel and
one is located along the bottom of the panel (Figure 11). Swing the panel out and hang it on the
screws located on the frame.
9. Fill the reservoir with coolant. NOTE: The reservoir only holds 1/2 of the required coolant for the
system.
10. Power the pump ON and watch the coolant begin
circulating. Keep adding coolant into the reservoir as
needed to prevent the fluid level from dropping below the
Minimum Fill Line. Continue running the system until the
coolant appears free from air bubbles.
Coolant Refill Instruction Sheet
020-100686-01 Rev. 1 (03-2011)
Figure 11 Remove Liquid Cooling Panel
Figure 12 Fill Reservoir