III A - work with RM-16A relay module - volt-free heating source control
14
Np.
VS30
HTRP230V(50)
L
N SL
SL
N
L
AC 230V
L
N
Connection of a 230 V AC voltage thermostat to a boiler
(or other device) with an ON - OFF contact.
Np.
VS30
L
N SL
SL
N
L
AC 230V
L
NO, COM, NC - voltage-free output
N
KL08NSB
L N SL
1 - 8 Strefy
Power
L N
L N
AC 230V
L
COM
NO
(input)
(wejście)
NO
COM
NC
RM-16A
Np.
091FL
COM
NO
Legend:
COM
NO
Boiler - Boiler connection* - Boiler's
(wejście)
NO
contacts for ON/OFF thermostat
(according to the boiler's instructions)
COM
NC
Symbols explanation:
L, N - power supply 230V
RM-16A
- SL - 230 V AC output signal
- fuse
AC 230V
L
N
MAX
16 (5) A
COM
NO
(wejście)
NO
SL
COM
N
NC
L
RM-16A
Np.
RT52
COM
COM
(wejści
SL
N
L
RM-16
T30