ANALOGICAL OUTPUT PARAMETERS (OPTIONAL)
This menu is only displayed if the optional analogical output is configured.
rAnGE.
ANALOGICAL OUTPUT RANGE [1506]
Select the analogical output field.
Selectable values:
0÷10 Vdc [0]
0÷5 Vdc [1]
4÷20 mA [2]
0÷20 mA [3]
Default: 0÷10 Vdc
NodE.
ANALOGICAL OUTPUT OPERATION MODE [1505]
Select the value to be associated with the analogical output, corresponding to net weight, gross weight,
or peak value.
Selectable values:
NET [0]
GROSS [1]
Default: NET
An 0.
ANALOGICAL OUTPUT ZERO VALUE [1501-1502]
Analogical value to be subtracted, referred to the analogical output's full scale.
An FS.
FULL SCALE [1503-1504]
The weight corresponding to the full scale of the analogical output.
Selectable value: 0 to Capacity
Default: Capacity
0f AdJ.
ZERO OFFSET ADJUSTMENT
Measure the analogical output value with a tester to perform zero-point calibration.
Use the
and
ZERO
Press the
key to return to the menu.
FS. A dJ.
FULL SCALE OFFSET ADJUSTMENT
Measure the analogical output value with a tester to calibrate the Full Scale (FS).
Use the
and
ZERO
Press the
key to return to the ANALOG menu.
This procedure is available to the user for adjustment, for each selectable range. In case of full reset of
the setup memory (with PC configuration), factory calibration values are restored.
Page 40
keys to adjust the analogical output. Press and hold the key for quick change.
keys to adjust the analogical output. Press and hold the key for quick change.