Setting up the automated zero parameter upon switch-on (AUTO 0) reduces (or annuls, in case of
"AUTO 0" > "0 BAND") the scope of action of the zero command.
AUTO-TARE
Autotare is not performed under the following conditions:
Unstable weight (the weight does not stabilize within 3 seconds of the reset command).
Gross weight equal to or greater than the maximum capacity of the weighing system.
After the unit is switched off, the AUTO TARE value is saved, only in case of FREE operating mode
selected and AUTO ZERO function deactivated.
ON-DEMAND TRANSMISSION
Serial transmission via the on-demand protocol is performed if the following conditions are in place:
• Stable weight (within 3 seconds from command).
• Weight changed by about 20 divisions since the last transmission performed (weight delta).
• Gross weight below maximum capacity.
• Only in case of METRIC operation, gross weight should be equal or lower than minimum weighing
(20 divisions).
• Only in case of METRIC operation, net and gross weight should be positive and not null.
WEIGHING SAVING
Weighing is saved in the alibi memory if the following conditions are in place:
• METRIC operation.
• Alibi memory option available in the unit.
• Stable weight (within 3 seconds from command).
• Weight changed by about 20 divisions since the last weighing performed (weight delta).
• Gross weight is equal to or lower than minimum weighing (20 divisions) and lower than maximum
capacity.
• Net and gross weight are positive and not null.
WEIGHT SET POINT SET-UP
The set-up value SET POINTs are compared against weight to drive the relevant logical output. The
comparator is selected in the logical input/output set-up procedure (see the corresponding section).
Press the FUN key to access Set point set-up; the FUN LED turns on; press key 1 within 2 seconds during