Gently slide the Sensor into the mounting bracket until the left and
right security brackets rest on the main brackets.
5.
Secure the Sensor with four each of the M6 screws, flat washers, and
lock washers included in the Mounting Kit.
6.
If desired, insert a padlock through the Mounting Bracket's side holes
to secure the Sensor.

Pole and Tower Mounting Instructions

To mount the RF Sensor to a pipe, use the following steps:
1.
Place the pipe bracket to the Mounting Bracket, placing the four
pipe bracket studs through the proper holes in the Mounting
Bracket.
Note that the illustration shows the pipe bracket installed for a vertical
pipe mount, but the pipe bracket can be rotated 90 degrees and installed
so that the sensor can be mounted on a horizontal pipe.
2.
Secure the pipe bracket to the Sensor Mounting Bracket using 4
M4 lock nuts.
The pole, tower, or pipe must be anchored and capable of
supporting 15 kg (33 lbs.) plus the weight of cables and
accessories.
N6841A RF Sensor Installation Guide