Graco Reactor 2 H-30 Repair Parts page 33

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
T8DA
Heater A
T8DB
Heater B
T8DH
Hose
V1IT
TCM
V2IT
TCM
334946H
Type
Description
Type
Type
Description
Description
No Temperature
Rise A
No Temperature
Rise B
No Temperature
Rise Hose
Low Voltage CAN
Low Voltage CAN
Cause
Solution
Cause
Cause
Solution
Solution
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10 kW
systems, 6-8 Ω for 15 kW
systems, 4–6 Ω for 20 kW
systems. If out of tolerance,
replace heater element.
Loose heater wires Check for loose heater
element wires.
Started spraying
Wait until operating
before heater
temperature has been
reached operating
reached before spraying or
temperature
recirculating.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10 kW
systems, 6-8 Ω for 15 kW
systems, 4–6 Ω for 20 kW
systems. If out of tolerance,
replace heater element.
Loose heater wires Check for loose heater
element wires.
Started spraying
Wait until operating
before heater
temperature has been
reached operating
reached before spraying or
temperature
recirculating.
Started spraying
Wait until operating
temperature has been
before heater
reached operating
reached before spraying or
recirculating.
temperature
Bad 24 VDC power
Check voltage of power
supply
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
Bad 24 VDC power
Check voltage of power
supply
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
Troubleshooting
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents