Graco Reactor 2 H-30 Repair Parts page 32

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Error
Error
Location
Location
T6DH
Hose
T6DT
TCM
32
Type
Description
Type
Type
Description
Description
Sensor Error Hose
Sensor Error TCM
Cause
Solution
Cause
Cause
Solution
Solution
Disconnected or
Expose each hose RTD
shorted RTD cable
connection to check and
in hose or bad FTS
retighten any loose con-
nector. Measure hose RTD
cable and FTS continuity.
See
page
kit 24N365 for measure-
ment.
Disconnect the hose RTD
and use Hose Manual Mode
or Hose Resistance Mode to
continue the job until repair
can be completed. Hose
Resistance Mode requires
a saved calibration factor.
Refer to your proportioner
operation manual to enable
Hose Control Modes.
Shorted RTD cable
Expose each hose RTD
in hose or FTS
connection to check for
exposed and shorted RTD
wires. Measure hose RTD
cable and FTS continuity.
See
page
kit 24N365 for measure-
ment.
Disconnect the hose RTD
and use Hose Manual Mode
or Hose Resistance Mode to
continue the job until repair
can be completed. Hose
Resistance Mode requires
a saved calibration factor.
Refer to your proportioner
operation manual to enable
Hose Control Modes.
Shorted A or B
If the error still occurs with
Heater RTD
the hose FTS unplugged,
one of the heater RTDs
is bad. Unplug the A or
B RTD from the TCM. If
unplugging an RTD fixes
the T6DT error, replace the
RTD.
Repair Heated Hose,
62. Order RTD Test
Repair Heated Hose,
62. Order RTD Test
334946H