Graco Reactor 2 H-30 Repair Parts page 22

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Error
Error
Location
Location
MMUX
USB
P0AX
HCM
P0BX
HCM
22
Type
Description
Type
Type
Description
Description
Maintenance Due -
USB
Pressure Imbalance
A High
Pressure Imbalance
B High
Cause
Solution
Cause
Cause
Solution
Solution
USB logs have
Insert a USB drive into the
reached a level
ADM and download all logs.
where data loss
will occur if logs are
not downloaded.
Pressure
Ensure material flow is
difference between
equally restricted on both
A and B material
material lines.
is greater than the
defined value
Pressure
Ensure that the pressure
imbalance is
imbalance value, on the
defined too low
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material
Fill the tanks with material.
Fluid leaking from
Check if heater
heater inlet rupture
and PRESSURE
disk
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
with a pipe plug.
Feed system
Check feed pump and
defective
hoses for blockage. Check
that feed pumps have
correct air pressure.
Pressure
Ensure material flow is
difference between
equally restricted on both
A and B material
material lines.
is greater than the
defined value
Pressure
Ensure that the pressure
imbalance is
imbalance value, on the
defined too low
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material
Fill the tanks with material.
Fluid leaking from
Check if heater
heater inlet rupture
and PRESSURE
disk
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
with a pipe plug.
Feed system
Check feed pump and
defective
hoses for blockage. Check
that feed pumps have
correct air pressure.
334946H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents