Troubleshooting
Error
Location
Error
Error
Location
Location
T4DA
Heater A
T4DB
Heater B
T4DH
Hose
30
Type
Description
Type
Type
Description
Description
High Temperature A
High Temperature B
High Temperature
Hose
Cause
Solution
Cause
Cause
Solution
Solution
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Flow too high
Use a smaller mix chamber
for temperature
that is rated for the unit in
setpoint, causing
use.
temperature
overshoots when
gun is de-triggered
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Flow too high
Use a smaller mix chamber
for temperature
that is rated for the unit in
setpoint, causing
use.
temperature
overshoots when
gun is de-triggered
Hose portion
Shade exposed hose from
exposed to an
hot sun or expose FTS to
excessive heat
same environment when
source, like hot
at rest. Uncoil entire hose
sun or coiled
before heating to avoid
hose, can pass
self-heating.
fluid more than
27°F (15°C) over
hose temperature
setting to the FTS
Setting the A or
Increase hose setpoint
B setpoint much
so it is closer to A and B
higher than hose
setpoints.
setpoint can cause
fluid more than
27°F (15°C) over
hose temperature
setting to reach the
FTS.
Cold ambient
Cold ambient temperature
temperature is
is chilling the FTS and
causing hose to
causing hose heat to stay
heat
on longer than needed.
Insulate the FTS area of the
hose so that it heats at the
same rate as the rest of the
hose.