Troubleshooting
Error
Location
Error
Error
Location
Location
T2DA
Heater A
T2DB
Heater B
T2DH
Hose
28
Type
Description
Type
Type
Description
Description
Low Temperature A
Low Temperature B
Low Temperature
Hose
Cause
Solution
Cause
Cause
Solution
Solution
Flow is too high at
Use a smaller mix chamber
current setpoint
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω for
15 kW systems. If out of
tolerance, replace heater
element.
Loose heater wires Check for loose heater
element wires.
Flow is too high at
Use a smaller mix chamber
current setpoint
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω for
15 kW systems. If out of
tolerance, replace heater
element.
Loose heater wires Check for loose heater
element wires.
Flow is too high at
Use a smaller mix chamber
current setpoint
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Cold chemical in
Recirculate heated
unheated portion
chemical back to drum
of system passed
in cold conditions before
hose FTS at
startup.
startup
334946H