Time program
6
Time program
6.1
Heating circuit
Individual heating circuits
The following adjustments can be made for each heating circuit separately:
• Select the standard program
• Modify the standard program by moving switching points
• Inserting or deleting switching points
• Delete or connect heating phases
6.1.1
Setting the room temperature
If the heating circuit has its own remote control, you can only adjust the
room temperature via the remote control.
To set the room temperature for heating mode or setback mode:
▶ Select heating circuit.
▶ Tap and hold the symbol and drag to the required temperature
( Fig. 25, [15], page 22).
▶ Tap Save.
To display the temperature for a switching point:
▶ Tap symbol briefly.
The actual temperature set for this switching point is displayed.
The room temperature can be adjusted separately for each time program.
6.2
Time program
The time program changes the operating mode automatically (heating
mode, setback mode) according to the times set. As the rooms reach the
required temperature at different rates, the times specified in the time
program must be harmonised with the building conditions (e.g. building
insulation, type of heating, use).
A number of different preset time programs are available as standard
programs. A custom program (User-defined) can also be created.
1
2
3
30
25
20
15
10
00:00
04:00
08:00
14 13 12
10
Fig. 25 Time program
[1]
Day of week
[2]
Dropdown list Day of week
[3]
Program
[4]
Dropdown list Program
[5]
Indoor temperature
[6]
Operation mode
[7]
Save
[8]
Active time program
[9]
Cancel
[10] Switching point
[11] Clock
[12] Set room temperature for heating mode
[13] Set room temperature for setback mode
[14] Indoor temperature
22
4
5
6
7
8
21°C
12:00
16:00
20:00
24:00
12:00
11
10
0010009478-001
6.2.1
Selecting a standard program
The default setting is the Family standard program.
▶ After commissioning, check whether the selected time program is
compatible with the lifestyle habits.
If not, several options are available for adapting the time program to your
individual requirements.
Time programs are only effective in automatic mode.
The following standard programs are available:
Program
Day
name
Family
Mo...Th
(default
Fri
setting)
Sat
Sun
Single
Mo...Th
Fri
Sat
Sun
Seniors
Mo...Sun 05:30
New
(custom
program)
Custom
If none of the standard programs suits your lifestyle, you
can modify a standard program ( Chapter 6.2.2,
page 23) or set a new time program ( Chapter 6.2.3,
page 23).
Table 6 Overview of standard programs
To select a standard program:
9
▶ Select heating circuit.
▶ Tap
symbol and select the weekday ( Fig. 25, [2], page 22)
and required program ( Fig. 25, [4], page 22) from the dropdown
list.
▶ Tap Save.
▶ If required, match the switching points and temperatures to the
specific lifestyle habits.
On
Off
On
Off
(heating
(setbac
mode)
k mode)
05:30
22:00
05:30
23:00
06:30
23:30
07:00
22:00
06:00
08:00
16:00 22:00
06:00
08:00
15:00 23:00
07:00
23:30
08:00
22:00
22:00
Control 8311/8313 – 6720859790 (2020/02)
On
Off