HoW To PoSITIoN THE LIMIT SWITCH BRACKETS
Manually open the gate, leaving 1 – 3 cm space, according
to the weight of the gate, between the gate/door and the
mechanical stopper A (Fig. 10).
Then fix the bracket of the limit switch S in order that the
micro-switch F of the limit switch is kept pressed.
After drilling two holes of ø 5.5mm, use the two screws G
supplied.
Repeat this operation with closed gate/door.
NOTE: The limit switch bracket should be positioned in order
to allow that the gate/door stops its movement without hitting
the mechanical stopper.

MANuAL oPERATIoN

In the event of power failure or faults, the gate can be ma-
nually operated as follows (Fig.10):
- Open the protective cap from the lock, introduce the cu-
stomized key supplied and turn it by 90° anti-clockwise.
- Remove the lock group, introduce the hexagonal key sup-
plied, and loosen the screws anticlockwise until the gate
leaves are released.
- The gear motor is released and the gate can be manually
opened or closed.
- To reset the normal operation, introduce the hexagonal
key one again and turn firmly clockwise until it is locked.
With an automatic operation check that no slipping occurs
when the gate leaf is moving.
- Apply the lock group again, making sure that the anti-
rotation pin be introduced in the hole on the gear group.
- Turn the key clockwise, then remove it and close the pro-
tection cap again.
CoNNECTIoN To GRouND (EARTH)
As regards the CoMPuLSoRY earthing, a special Faston
4-pin connector fitted onto the central support (Fig. 12 –
CARTER-GND) is supplied. Ground connections of the upper
removable side and the lower side can be connected to this
Faston.
To allow an easy removal of the sides, they are not supplied
pre-cabled to the connector. The installer shall provide for
their connection, by using the already equipped with Faston
terminal.
As shown in Figure 12, mains power supply should be
connected to the mains filter (Fig. 12-FILTER), while for
grounding the special terminal should be in use (Fig.
12-GND).

WIRE DIAGRAM

Figure 13 shows the cables to the preset for the installation
of the gear motor and the main accessories.
As regards the wire connection of the automatic system and
the adjustment of the operating modes, see the instruction
manual of the control unit.
Before introducing the cables, check the type of cabling
required for the accessories actually used.
Key of components:
1
Gear motor with BISON built-in control unit.
2
Rack
3
Limit switch brackets
4
Photocells
5
Mechanical stoppers
6
Key selector or digital keypad
7
Flashing light
8
Antenna
Note: The removable side of the BISON gear motor comes
already preset for the mounting of the FTC.S photocells.
12
WARNING
The RC product insurance policy, which covers any injuries
or damages to objects caused by manufacturing defects,
requires the use of Benincà's original accessories.