5.2 FAULT FINDING MENU

ERROR TYPE
(Warning, Blocking,
Lockout)
HARDWARE (THERMISTORS, ACTUATORS)
B
Flow thermistor open circuit (blocking)
B
Flow thermistor short circuit (blocking)
B
Return thermistor open circuit (blocking)
B / W
Return thermistor short circuit (blocking)
B / W
Flue thermistor open circuit (blocking)
B
Flue thermistor short circuit (blocking)
W
DHW thermistor open circuit
W
DHW thermistor short circuit
W
Outside thermistor defect (open / short)
B
Water pressure sensor defect
L
Flow thermistor open circuit (lockout after 24h)
L
Flow thermistor short circuit (lockout after 24h)
L
Return thermistor open circuit (lockout after 24h)
L
Return thermistor short circuit (lockout after 24h)
L
Flue thermistor open circuit (lockout after 24h)
L
Flue thermistor short circuit (lockout after 24h)
L
Heat thermistor open circuit (lockout after 24h)
L
Heat thermistor short circuit (lockout after 24h)
B
Heat thermistor open circuit (blocking)
B
Heat thermistor short circuit (blocking)
W
Header thermistor open circuit
W
Header thermistor short circuit
W
Room (hc1) thermistor open circuit
W
Room (hc1) thermistor short circuit
TEMPERATURE SUPERVISIONS
Blocking due to flow overheat
B
B
Blocking due to return overheat
Blocking due to flue overheat
B
B
Flow & return reversed
B
Flow gradient supervision
B
Flue gradient supervision (reserved)
Blocking delta temp flow/return
B
Lockout flow overheat
L
L
Lockout return overheat
Lockout flue overheat (flue thermistor)
L
Lockout thermal fuse (thermal fuse)
B
Blocking due to heat exchanger overheat
SYSTEM (FLAME, FAN, HYDRAULIC, ETC.)
Blocking due to no CH water flow
B
B
Low water pressure
No flame signal at start (restart)
W
Flameloss during operation => endless restarts (Parameter "endless restarts" activated)
W
Flameloss during operation, => Lockout after restarts attempts are used (Parameter "endless restarts" deactivated)
L
Flameloss during stabilisation => restart attempts
W
Flameloss during stabilisation => Lockout after restarts attempt are used
L
False flame (with heat demand)
L
No flame after restarts
L
B/L
Fan speed, stand still check
L
Fan speed not achieved, e.g. Pre-purge-test, post-purge-test etc.
Error fan speed during pre-purge (5* restarts => lockout )
B/L
W
Error min/max supervision fan speed during operation (restart)
W
Warning due to mains overvoltage
B
Blocking due to mains undervoltage
Opentherm plus error (communication faulty; no connection anymore , etc)
W
L
Too many remote resets
HX water flow fault (feedback < min flow rate)
B
66
SECTION 5 - FAULT FINDING
DESCRIPTION
ERROR
REFER TO
CODE
SECTION...
(OpenTherm)
1
5.9
2
5.9
3
5.9
4
5.9
5
n/a
6
n/a
7
5.12
8
5.12
9
5.10
10
n/a
11
5.9
12
5.9
13
5.9
14
5.9
15
n/a
16
n/a
17
5.9
18
5.9
19
5.9
20
5.9
21
5.10
22
5.10
23
5.10
24
5.10
30
5.3
31
5.3
32
n/a
33
5.11
36
5.3
37
n/a
38
5.3
39
5.3
40
5.3
41
1-6
42
5
50
1-4, 6
51
5.6
52
5.7
53
5.7
54
5.7
55
5.7
56
5.7
57
5.7
58
5.4
59
5.8
60
5.8
61
5.8
62
5.8
63
check mains supply
64
check mains supply
65
5.14, 5.15
66
power cycle the boiler
70