14.14.1.7 Setting Position Judgment
According to installation position when there is only one activity area detected, the horizontal airflow direction
louver position is fixed according to chart below:
Target area
A
B
C
Louver position refer to horizontal airflow direction control.
When 2 activity areas have been detected, according to Human Activity Level, the timing of horizontal airflow
direction louver steps at the targeted activity areas is judged.
Operation mode
Cooling
Heating
When 3 activity areas have been detected, according to Human Activity Level the timing of horizontal airflow
louver steps at the targeted activity areas is judged.
Operation mode
Cooling
Heating
When 3 activity areas have same activity level, the horizontal airflow direction louver will swing left and right.
14.14.1.8 Setting Temperature
Cooling Dual Sensor
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Human
Mode
COOL/DRY
Set
temperature
HEAT
Horizontal airflow direction louver position
Left installation
Center installation
3
1
5
Activity level difference
1 level
2 levels
1 level
2 levels
Activity level
Hi
Me
Lo
Hi
Me
Lo
Low activity
Normal activity
+1 °C
Right installation
2
1
5
Louver stop time
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 30 seconds
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 8 seconds
Higher Activity level ≈ 8 seconds
Lower Activity level ≈ 30 seconds
Higher Activity level ≈ 8 seconds
Lower Activity level ≈ 60 seconds
Louver stop time
≈ 45 seconds
≈ 30 seconds
≈ 20 seconds
≈ 20 seconds
≈ 30 seconds
≈ 45 seconds
High activity
Absent
-2 °C
96
2
1
4
+2 °C
-2 °C