20.3 Piping Length Correction Factor

The characteristic of the unit has to be corrected in accordance with the piping length.
20.3.1
CS-Z20TKR CU-Z20TKR CS-Z25TKR CU-Z25TKR CS-Z35TKR CU-Z35TKR
1.05
1.00
0.95
0.90
0.85
0
1
2
3
1.05
1.00
0.95
0.90
0
1
2
3
Note: The graphs show the factor after added right amount of additional refrigerant.
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
Pipe Length (m)
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
Pipe Length (m)
184
Cooling Capacity
3
1.0010
5
1.0000
7.5
0.9793
15
0.9107
20
0.9085
Heating Capacity
3
1.0060
5
1.0000
7.5
0.9979
15
0.9773
20
0.9675