Service Data; Cool Mode Outdoor Air Temperature Characteristic - Panasonic CS-Z20TKR Service Manual

Indoor/outdoor units
Hide thumbs Also See for CS-Z20TKR:
Table of Contents

Advertisement

20. Service Data

Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.

20.1 Cool Mode Outdoor Air Temperature Characteristic

Condition
- Indoor room temperature: 27°C DryBulb/19°C Wet Bulb
- Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
- Compressor frequency: Rated for cooling operation
- Piping length: 5m
- Voltage: 230/240V
20.1.1
CS-Z20TKR CU-Z20TKR
2.600
2.400
2.200
2.000
1.800
1.600
1.400
1.200
16
18
20
22
1.400
1.300
1.200
1.100
1.000
0.900
0.800
16
18
20
22
21.000
20.000
19.000
18.000
17.000
16.000
15.000
16
18
20
22
24
26
28
30
32
34
36
Outdoor Temperature (℃)
24
26
28
30
32
34
36
Outdoor Temperature (℃)
24
26
28
30
32
34
36
Outdoor Temperature (℃)
230V
240V
38
40
42
44
46
230V
240V
205.000
190.000
175.000
160.000
145.000
130.000
115.000
38
40
42
44
46
230V
240V
38
40
42
44
46
168
Current (A)
Outdoor
Temperature (°C)
230V
16
1.290
25
1.580
35
2.000
46
2.460
Outdoor
Lo Pressure
Temperature (°C)
(MPa)
16
0.861
25
1.006
35
1.160
46
1.346
Outdoor
Indoor Discharge
Temperature (°C)
Air Temperature (°C)
15.950
16
25
15.470
16.870
35
20.630
46
240V
1.240
1.530
1.950
2.410
Lo Pressure
(Psi)
124.878
145.908
168.244
195.221

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents