Panasonic CS-Z20TKR Service Manual page 91

Indoor/outdoor units
Hide thumbs Also See for CS-Z20TKR:
Table of Contents

Advertisement

Indicator
When nanoe-G starts, nanoe-G indicator ON.
o
Remote Control Receiving Sound
Normal Operation
o
nanoe-G Operation
o
Stop
o
nanoe-G individual Operation
o
Power failure
During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual
o
operation resumes immediately.
During combination operation, if power failure occurs, after power resumes, combination operation resume
o
immediately.
nanoe-G check mode
To enable nanoe-G check mode, during nanoe-G operation ON:
o
If there is abnormal discharge, nanoe-G indicator blinks immediately.
o
Error detection control
When nanoe-G indicator blinks, it indicates error listed below:
nanoe-G connector at main PCB open
o
Judgment method
During nanoe-G operation, nanoe-G connector at main PCB is opened.
Troubleshooting method
Connect the connector or stop operation to cancel the blinking.
Switch off the power supply and unplug before cleaning.
Clean the dirty nanoe-G generator with cotton bud.
Abnormal discharge error
o
Judgment method
During nanoe-G operation, the nanoe-G system has abnormal discharge due to short-circuit caused
by water or dust adhesion and so forth, with Lo-feedback voltage (at microcontroller).
When abnormal discharge occurred, every 30 minutes the unit supplies power to the nanoe-G
system.
When abnormal discharge occurs for 24 times continuously, nanoe-G indicator blinks.
 nanoe-G Operation
 Normal Operation
 nanoe-G individual Operation
 Stop
iCOMFiAUTO-XHEATCOOLDRYFAN
SHOWER
DIRECT
Remote control normal mode
ON
AM
PM
OFF
AM
PM
Press continously for 5s
SET
Transmit ECO demo code and
after 30 seconds return to normal
mode.
Transmit sunlight sensor check code
and after 30 seconds return to normal
mode.
Transmit check code
and after 30 seconds return to normal
mode.
91
: Beep
: Beep
: Beep
: Long Beep

Hide quick links:

Advertisement

Table of Contents
loading