21.2 Heat Mode Outdoor Air Temperature Characteristic

Condition
- Indoor room temperature: 20°C DryBulb/-°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230-240V
21.2.1
CS-RZ25VKRW CU-RZ25VKR
3.600
3.400
3.200
3.000
2.800
2.600
2.400
2.200
2.000
-16 -14 -12 -10 -8 -6 -4 -2 0
3.100
2.900
2.700
2.500
2.300
2.100
1.900
1.700
1.500
-16 -14 -12 -10 -8 -6 -4 -2 0
42.000
40.000
38.000
36.000
34.000
32.000
30.000
28.000
26.000
24.000
-16 -14 -12 -10 -8 -6 -4 -2 0
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
230V
240V
230V
240V
449.000
420.000
391.000
362.000
333.000
304.000
275.000
246.000
217.000
230V
240V
177
Current (A)
Outdoor
Temperature (°C)
230V
-15
2.280
-7
2.610
2
2.800
7
3.000
24
3.500
Outdoor
Hi Pressure
Temperature (°C)
(MPa)
-15
1.564
-7
1.961
2
2.115
7
2.203
24
2.900
Outdoor
Indoor Discharge
Temperature (°C)
Air Temperature (°C)
-15
24.700
-7
29.860
31.340
2
33.700
7
41.960
24
240V
2.180
2.510
2.700
2.900
3.400
Hi Pressure
(Psi)
226.839
284.419
306.755
319.518
420.609