21.2.4
CS-RZ50VKRW CU-RZ50VKR
10.000
9.000
8.000
7.000
6.000
5.000
-16 -14 -12 -10 -8 -6 -4 -2 0
3.600
3.400
3.200
3.000
2.800
2.600
2.400
2.200
2.000
1.800
-16 -14 -12 -10 -8 -6 -4 -2 0
50.000
45.000
40.000
35.000
30.000
25.000
-16 -14 -12 -10 -8 -6 -4 -2 0
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
2
4
6
8 10 12 14 16 18 20 22 24
Outdoor Temperature(℃)
230V
240V
230V
240V
522.000
493.000
464.000
435.000
406.000
377.000
348.000
319.000
290.000
261.000
230V
240V
180
Current (A)
Outdoor
Temperature (°C)
230V
-15
5.290
-7
5.630
2
6.340
7
6.900
24
9.620
Outdoor
Hi Pressure
Temperature (°C)
(MPa)
-15
1.863
-7
2.012
2
2.216
7
2.484
24
3.438
Outdoor
Indoor Discharge
Temperature (°C)
Air Temperature (°C)
27.050
-15
28.760
-7
32.140
2
35.110
7
47.400
24
240V
5.190
5.530
6.240
6.800
9.520
Hi Pressure
(Psi)
270.205
291.816
321.404
360.274
498.640