5
Secure the connection cable onto the control board with the holder.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's
o
respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
o
WARNING
This equipment must be properly earthed.
12.2.4.1

Wire Stripping, Connecting Requirement

Wire stripping
No loose strand
when inserted
Indoor/outdoor
connection
terminal board
5 mm or more
(gap between wires)
Conductor
Conductor over
fully inserted
inserted
ACCEPT
PROHIBITED
Connection cable
Indoor & outdoor
connection cable
Escapement
Recommended
length (mm)
a
b
Recommended
length (mm)
35 35 35 55
WARNING
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
OVERHEATING AND
FIRE.
Conductor not
fully inserted
PROHIBITED
Terminal Board
Tape
Holder
Indoor & outdoor
connection cable
Outdoor unit
c
d
OR
Do not joint wires
OR
64
Earth Wire
longer than
others AC
wires for
safety reason
Use complete wire
without joining.
Use approved socket
and plug with earth pin.
Wire connection in this
area must follow to
national wiring rules.
OR