Horizontal Airflow (Rz50/60/71/80Vk); Control Condition; Quiet Operation (Cooling Mode/Cooling Area Of Dry Mode) - Panasonic CS-RZ25VKRW Service Manual

Indoor/outdoor units
Hide thumbs Also See for CS-RZ25VKRW:
Table of Contents

Advertisement

14.4.3

Horizontal Airflow (RZ50/60/71/80VK)

Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Heating, with heat exchanger temperature
Cooling and soft dry
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Pattern
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)
* The vertical vane angle tolerance is within +/- 5 degree.

14.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

Purpose
To provide quiet cooling operation compare to normal operation.
o

Control condition

Quiet operation start condition
o
When "QUIET" button at remote control is pressed.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET is pressed.
Stop by OFF/ON switch.
Timer "off" activates.
ECO button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer "on" activates, quiet operation maintains.
After off, when on back, quiet operation is not memorized.
Control contents
Fan speed is changed from normal setting to quiet setting of respective fan speed.
o
Fan speed for quiet operation is reduced from setting fan speed.
o
Operation Mode
A: swing
43°C
B: fix front
Indoor Heat Exchanger
Temperature
Figure1
1
90
A
B
40°C
2
3
1
Figure 2
2
3
70
80
103
Vane Angle (°)
70 ~110
90
70 ~110
Top View
5
4
4
100
5
110