Quantum Scalar i40 and Scalar i80: System Control Board Replacement
6-66556-04 Rev B
February 2014

Replacing the System Control Board

Installing Library Firmware

4
These instructions explain how to replace the defective SCB.
1 Position the new SCB for installation as follows:
a Place the board components face up. (The flat part of the board faces
down.)
b Be sure the thumbscrews are on the upper side of the SCB back plate
(see
Figure 1
on page 3).
2 To install the new SCB, complete the following steps:
a Push the SCB into the slot until it stops.
It should slide smoothly and easily.
b When it reaches the end of its travel, press firmly on the back panel of
the SCB to "snap" it into place.
c Tighten the two thumbscrews finger tight.
3 Connect the Ethernet cable to the LEFT Ethernet port on the SCB (as viewed
from the back of the library; see
These instructions explain how to install the firmware for the library.
1 Connect the power cords to the power supplies on the back of the library.
Make sure that each power supply is plugged into a grounded AC outlet.
2 To turn the library ON, press the power button on the front panel.
The LED on the SCB should illuminate green. The green power LED on the
library front panel above the power button illuminates, and the Operator
panel screen turns on. The library goes through a connection and
initialization sequence that takes up to 60 seconds.
When initialization is complete, the Library Installation screen appears on
the Operator panel, displaying the text, "
its IP Address configured
address so you can access the library via the Web client and download
firmware. (After you have loaded firmware, you can change or reconfigure
IP addresses, if needed.)
3 From the Operator panel, press Next.
The screen displays the text, "
"
to IPv6?
4 Press one of the following options:
• Yes — The library supplies a stateless IPv6 address and displays it, along
with other network settings, on two screens. Use the Next and Back
Figure 1
on page 3).
The library needs to have
." The purpose of this screen is to set the IP
Current protocol: IPv4. Set protocol
Replacing the System Control Board