The Ei158 Kit is similar but also includes a relay for switching
250V AC / 5 amps. This is useful for remote signalling and turning
on lights.
Smoke Alarm Locator Ei159:
The Smoke Alarm locator is recommended for systems with three
or more Smoke / Heat Alarms as it helps quickly identify the unit
in alarm and reduces the impact of nuisance alarms.
When three or more units are interconnected with alarms
sounding, pressing the Smoke Alarm Locator button will silence
all units for 10 minutes, except those sensing fire. It is easily
installed between the interconnect and neutral wires.
Smoke Alarm - Optical or Ionisation?
Both types respond in all standard fires but each type may
respond faster to particular fires as shown.
Optical Sensor
Best for slow smouldering fires
- large smoke particles
Fire Authorities states:
"If your home has more than one floor, at least one alarm should
be fitted on each level".
FIVE YEAR PRODUCT GUARANTEE
Ei Electronics guarantees this Smoke Alarm for five years from date
of purchase against any defects that are due to faulty materials or
workmanship. This guarantee only applies to normal conditions of
use and service, and does not include damage resulting from
accident,
neglect,
contamination howsoever caused. This guarantee excludes
incidental and consequential damage. If this Alarm should become
defective within the guarantee period, it must be returned to the Ei
Electronics, with proof of purchase, carefully packaged, with the
problem clearly stated. (see "Getting Your Alarm Serviced") We
shall at our discretion repair or replace the faulty unit.
Do not interfere with the Smoke Alarm or attempt to tamper with it.
This will invalidate the guarantee, but more importantly may expose
the user to shock or fire hazards.
This guarantee is in addition to your statutory rights as a consumer.
ALARM SOUNDS FOR NO APPARENT REASON:
(1) Identify the alarm source. On all interconnected units, the red
light under the test button or on the cover will flash rapidily
only on the unit which is the source of the alarm.
misuse,
unauthorised
TROUBLESHOOTING
13
Ion Sensor
Best for fast flaming fires
- small smoke particles
dismantling,
or