❺ Use

5.1 I User interface

• Before activating the chlorination function on the appliance, check that the minerals added to
the pool have completely dissolved.
Blue
indicator on steady:
Too low water conductivity (low minerals,
water too cold, worn cell, etc.)
Activate/Disable LOW mode:
Chlorine production reduced to between
0% and 30% in intervals of 10% (can be
configured in the relevant MENU).
The "LOW MODE ON" message is
displayed.
User menu:
Setting the parameters.
arrows:
- Browse a menu
- Increase or decrease a setting value
- Lock/unlock the user interface (Press
the 2 buttons simultaneously for 4
seconds).

5.2 I Configuration before use

5.2.1 Switching on
• Press
to switch the appliance on.
• The appliance's information is displayed on start-up:
5.2.2 Setting the language
• On first start-up, the list of available languages is displayed; simply select the desired language using the
buttons. Confirm the selection by pressing
• To change the language at a later point, press
• Confirm the selection by pressing
*
Wi-Fi LED
.
and browse using the
.
Blue
indicator on steady or
flashing:
View information or action to be performed
on the screen.
Switch on -/Switch off (press and hold)/
Switch to standby(press and release)
Activate BOOST mode:
Chlorine production at 100% for a
cumulated 24 hours. The "BOOST ON"
message is displayed with the time
remaining.
button:
- Confirm the highlighted selection
- Delete an error message requiring
human intervention (press and hold for
4 seconds)
To activate Wi-Fi Direct mode to
connect to the iAquaLink™ app
(Press both buttons until the Wi-Fi LED
starts to flash)
See "6.1 I
Configuring the appliance
before first use".
buttons.