• Screw the one or more threaded sensor holders onto the POD kit, see figure
• Carefully unscrew the protection tube from the sensor, see figure
the sensor over winter.
• Rinse the end of the sensor with tap water and shake off excess water, see figure
• Never wipe the sensor using a cloth or paper tissue, as this may damage it.
• A badly-installed sensor may give false readings and cause inappropriate operation of the
appliance. Neither the manufacturer nor the appliance shall be liable in this event.
• Screw the sensor into the sensor holder by holding the BLUE or YELLOW tip in one hand and the black tip
in the other hand to prevent the cable from tangling, see figure
• Once the sensor has been installed on the POD kit, it can be connected to the BNC socket (BLUE = pH;
YELLOW = ORP) of the pH Link or Dual Link module, see "2.5.2 Identifying the functions to be connected",
see figure
.
• The sensor must then be calibrated, see "5.3 I Calibrating the sensors (if an optional "pH Link" or "Dual
Link" module has been installed)".
.
. Keep the protection tube for storing
.
.