Advertisement

iAquaLink
Web Connect Device
For use with the following Systems:
AquaLink
RS Systems: Rev R Firmware or later
®
AquaLink PDA Systems: Rev 6.0 Firmware or later
AquaLink Z4 Systems: All Firmware versions
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in
pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so
that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all
warning notices and instructions that accompany this product. Failure to follow warning notices and instructions
may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property
damage, or death.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Modifications made to this equipment, which are not authorized by the manufacturer, may void the user's authority
to operate this equipment.
™ 2.0
WARNING
ATTENTION
INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Zodiac iAquaLink 2.0

  • Page 1 INSTALLATION MANUAL iAquaLink ™ 2.0 Web Connect Device For use with the following Systems: AquaLink RS Systems: Rev R Firmware or later ® AquaLink PDA Systems: Rev 6.0 Firmware or later AquaLink Z4 Systems: All Firmware versions WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 3: Table Of Contents

    NOTE Section 1. Important Safety Instructions ..4 Section 5. Web Interface Home Screen ..11 Title Bar ............12 Section 2. Overview of the iAquaLink 2.0 Web Middle Info Panel ..........12 Connect Device ....... 6 Navigation Bar ..........12 AquaLink 2.0 Requirements ......6 Dialog Boxes ...........12...
  • Page 4: Section 1. Important Safety Instructions

    Page 4 ENGLISH iAquaLink™ Web Connect Device for AquaLink Control Systems Installation Manual ® Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER...
  • Page 5 ENGLISH Page 5 iAquaLink™ Web Connect Device AquaLink Control Systems Installation Manual ® WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Page 6: Section 2. Overview Of The Iaqualink 2.0 Web

    Welcome, and thank you for purchasing the iAquaLink or later, skip to section 4 of this manual. 2.0 Web Connect Device! The iAquaLink 2.0 Web Connect Device connects an Replacement of the CPU Board AquaLink System to the Internet through your existing This step is for the AquaLink RS with revision N residential internet service.
  • Page 7: Replacement Of The Power Center Pcb And Bezel Assembly And Cpu Board

    R or later. Reinstall the power center PCB and bezel assembly The iAquaLink 2.0 device can be installed outdoors, on in the power center can using the screws previously the equipment pad, or inside your home with a choice of removed.
  • Page 8: Outdoor Installation

    6’ Turn off all power to the power center. (1,8 m) Mount the outdoor iAquaLink 2.0 J-box at least six (6) feet (1,8 m) above the ground, at least ten (10) Voltage feet (3 m) from any motor or air blowers that may Area be in the vicinity, and at least five (5) feet (1.5 m)
  • Page 9: Set Up The Iaqualink 2.0 Device For Wireless Connection

    WPS Method. iAquaLink 2.0 device. For wired connection skip to Section 4.5 Install the iAquaLink 2.0 device at least six (6) feet Connect iAquaLink to the Home Network - (1.8 m) above the ground and at least five (5) feet WiFi Hotspot Method (1.5 m) away from other transceiver J-boxes.
  • Page 10: Set Up The Iaqualink 2.0 Device For Wired Connection

    (Does not apply to wi-fi installations). Remove the two (2) screws that secure the cover Inside the iAquaLink 2.0, toggle the WiFi - Wired and gasket on the iAquaLink 2.0 device. Remove switch to clear the Wi-Fi settings and put the iAquaLink in desired setup mode.
  • Page 11: Account And Location Setup

    ENGLISH Page 11 iAquaLink™ Web Connect Device for AquaLink Control Systems Installation Manual ® Account & Location setup • If the location to be programmed or controlled is shown, click on the location name. If it is not shown, click the [Add Location] button, and follow the prompts to add the Make sure all three (3) LED status indicator NOTE...
  • Page 12: Title Bar

    Page 12 ENGLISH iAquaLink™ Web Connect Device for AquaLink Control Systems Installation Manual ® Title Bar HOME > MENU Menu The title bar displays the title of the screen and the Thu June 23, 2011 3:03 PM current date/time. The title of the current menu in use Schedule Set Temp Date/Time...
  • Page 13: Scheduling And Adding Devices

    ENGLISH Page 13 iAquaLink™ Web Connect Device for AquaLink Control Systems Installation Manual ® Schedule Devices Set Date/Time Thu June 23, 2011 3:03 PM Thu June 23, 2011 3:03 PM Devices Time: 00:00 Filter Pump Date VSP Pump 01/01/09 Pool Heat Spa Heat Chiller Time...
  • Page 14: Customize Home

    Page 14 ENGLISH iAquaLink™ Web Connect Device for AquaLink Control Systems Installation Manual ® ON/OFF Times MENU > CUSTOMIZE HOME MENU > SCHEDULE > EDIT > START TIME Customize Home Thu June 23, 2011 3:03 PM General Items 1) Select label group General Schedule Page...
  • Page 15: Section 7. Troubleshooting

    Problem Possible Solution The iAquaLink 2.0 is on and The iAquaLink 2.0 is not Check the cabling to the iAquaLink 2.0 Web- the startup screen is displayed. communicating with the power Connect device (all conductors). The override switches at the center PCB.
  • Page 16 ABN 87 002 641 965, 219 Woodpark Rd, Smithfield NSW 2164, Australia ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license. All trademarks referenced herein are the property of their respective owners. ©2013 Zodiac Pool Systems, Inc. H0435500 Rev B...

Table of Contents