2.2 I Installing the temperature sensor
• The water temperature sensor displays the water temperature value on the appliance screen and manages
chlorination according to the temperature. The sensor must measure the temperature of the water
upstream of any possible heating system.
• The sensor is designed to be mounted on rigid Ø50 mm, Ø63 mm or Ø1 ½'' PVC pipes. Do not install on any
other type of pipe.
• Install the sensor either between the filter pump and the filter, or between the filter and any other
downstream equipment, see "2.1 I Installing the cell":
Drill a hole in the pipe using a Ø9 mm (max. Ø10 mm) drill bit, then deburr the hole,
-
- Install the O-ring provided on the sensor body,
- Secure the sensor using the stainless-steel clamping collar provided. Do not use excess strength.
2.3 I Installing the flow switch
In cases where a pH Link or Dual Link module is used, the flow switch will be installed on the POD
Kit, see "3.3 I Installing the flow switch on the POD kit"
• The flow switch and its 50 mm diameter fixture collar supplied as standard (63 mm diameter available
as a spare part) must be installed immediately before the cell and after any valves present (
threaded adapter and the Teflon tape provided to install the flow switch on its fixture collar.
• Screw the flow switch using using the clamping nut only (screw by hand!) (
Installation on a by-pass
• Failure to comply with these instructions could lead to the destruction of the cell! The
manufacturer cannot be held liable in this case.
• The flow switch has a direction for installation (arrow indicated on it showing the flow
direction for the water). Make sure that it is correctly placed on its fixture collar so that it
stops the appliance's production when filtering is stopped.
(chlorinator only without pH Link or Dual Link modules)
In-line installation
: Sensor
:
O-ring
:
Stainless steel clamping collar
).
Direction of water
Clamping
nut
EN
). Use the
flow
9