5. Batteries are preferably charged by
current showed in Table 2. Keep vent
plugs removed during charging.
< Table 2 >
N70ZL
75D26L
TYPE
Volt (V)
12
12
Number of
plate per
15
13
cell
Capacity
at
70
65
20H.R
(A.H.)
Volume of
Electrolyte
4.7
4.2
( )
Normal
Charging
7
7
Rate(A)
6. Check temperature of electrolyte, if it
reaches 40°C (105°F), lower the
charging rate. When temperature is too
high, reduce charging rate and charge
for a proportionately longer period.
PT80 -
7. If the tractor is stored after original
34FR
charge, periodically recharge as
shown below :
12
< Table 3 >
-
Period of storage
from manufacture
(months)
0 ~ 6
100
6 ~ 12
over 12
A battery is fully charged when the
5.4
cells are all gassing freely and the
specific gravity ceases to rise for
three consecutive readings taken at
hour intervals. Specific gravity shall
5 ~ 10
then be adjusted to showed in Table
1.
8. Check electrolyte level two hours af-
ter chargingis finished and correct it.
Fresh charging
(times)
about 5 hours
10
30
MAINTENANCE 6-19