September 2004
66 -
Swtich
Switch
Name
Position
SW100
ON
Termination
SW200
SW300
SW400
OFF
Termination
CN102
ON
With S-Bus
CN202
the Feeding
CN302
CN402
supplied to
the terminal.
OFF
With T-Bus
the Feeding
Power is not
ISDN BRI CONNECTOR (RJ45) T-BUS CONNECTIONS
Result
This switch should be set to ON:
resistor is
1. When T-Bus with Point-to-Point is
ON
selected.
2. When T-Bus with Point-to-Multipoint
is selected and if the Topaz system is
not connected to the last port of the
Bus connection, this switch should be
OFF.
3. When S-Bus is selected.
When T-Bus with Point-to-Multipoint is
resistor is
selected and if the Topaz system is not
OFF
connected to the last port of the Bus
connection, this switch should be OFF.
If S-Bus is selected, this switch should be
selected,
ON if the connected device requires line
power.
Power is
If T-Bus is selected, this switch should be
selected,
OFF.
required.
Pin No.
NEC Business Solutions Ltd
Comments
Connections
1
2
3
TA
4
RA
5
RB
6
TB
7
8
Installing the Optional Facilities