9. SSD cage
Next steps
1. Install the SSDs in their original locations.
2. Follow the procedure listed in the After working inside your system section.
Related references
Instrucciones de seguridad
Related tasks
Before working inside your system
Removing a 1.8-inch (x16) SAS SSD backplane
Después de trabajar en el interior de su equipo
Storage controller card
Your system includes dedicated expansion-card slots on the system board for a storage controller card that provides the
integrated storage subsystem for your system hard drives/PCIe SSDs. The storage controller card supports SAS hard drives.
NOTE:
The storage controller card is located underneath the drive bays.
NOTE:
The storage controller card is installed on the system board connector labeled as MiniPERC CARD.
Removing the storage controller card
Prerequisites
CAUTION:
Muchas de las reparaciones deben ser realizadas únicamente por un técnico de servicio autorizado. El
usuario debe llevar a cabo únicamente las tareas de solución de problemas y las reparaciones sencillas
autorizadas en la documentación del producto o indicadas por el personal de servicio y de asistencia en línea o
telefónica. Los daños causados por reparaciones no autorizadas por Dell no están cubiertos por la garantía. Lea y
siga las instrucciones de seguridad que se envían con el producto.
NOTE:
This is a Field Replaceable Unit (FRU). Removal and installation procedures should be performed only by Dell
certified service technicians.
NOTE:
You must remove the storage controller card to replace a faulty storage controller card or service other components
inside the system.
1. Follow the safety guidelines listed in the Safety instructions section.
2. Follow the procedure listed in the Before working inside your system section.
3. Keep the #2 Phillips screwdriver ready.
4. Remove the following:
a. hard drives or SSDs
b. hard drive backplane or SSD backplane
c. hard drive cage or SSD cage
Steps
1. Loosen the two retention screws on the hard-drive backplane or SSD backplane cable connector and lift it away from the
storage controller card.