FILLING:
Place an empty container on the scale.
Press the T key.
The display shows the net value and the pointers stp1 and stp2 are on.
Relays 1 and 2 are closed.
As soon as set-point 1 is reached, pointer stp1 will turn off and relay 1 will be
opened.
As soon as set-point 2 is reached, pointer stp2 will turn off and relay 2 will be
opened.
The display shows "done" for a few seconds and will return in the normal
weighing mode.
The net weight is displayed. A printout may be made at this point.
It is possible to cancel the filling procedure at any time by pressing the CE key (see
page 18).
DOSING:
Place a full container on the scale.
Press the T key.
The display shows the net value and the pointers stp1 and stp2 are on.
Relays 1 and 2 are closed.
As soon as set-point 1 is reached, pointer stp1 will turn off and relay 1 will be
opened.
As soon as set-point 2 is reached, pointer stp2 will turn off and relay 2 will be
opened.
The display shows "done" for a few seconds and returns in the normal
weighing mode.
The net weight is displayed. A printout may be made at this point.
It is possible to cancel the dosing procedure at any time by pressing the CE key (see
page 18).
The printout will show the following:
-
The gross weight is the weight of the container with rest material.
The tare weight is the weight of the container with material before dosing.
-
The net weight will show a minus sign as token of weight being removed from the
-
scale.
DOSING / FILLING with Automatic Tare & Start
In this setting set-point 1 and 2 are switched on as soon as the set-point values have
been entered. The tare action is done automatically in this mode.
To enter new set-point values:
Press the
key.
The display shows the last entered value with the left digit blinking. The pointer
for set-point 1 is on.
Press ↵ to accept the old value.
The value for set-point 1 is activated. The display shows the last entered value
for set-point 2 with the left digit blinking. The pointer for set-point 2 is on.
15