Place Of Installation; Installation In Older Systems And Systems Requiring Modernisation; Water Connections - Riello BOLLITORE 120 Lt Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 38
3.4

Place of installation

The BOLLITORE 120 Lt appliance can be installed in all premises
permitted to appliances that are in conformity with the IP 40
degree of electrical protection.
3.5
Installation in older systems and systems
requiring modernisation
When the
R
BOLLITORE 120 Lt appliance is installed on old
systems or ones that need modernising, make sure that:
− Make sure that the system is fitted with safety and
control devices in accordance with applicable legislation
and standards
− Make sure that the central heating circuit has been flu-
shed out to remove all sludge and lime scale, and has
been vented and seal tested
− Make sure that a suitable water treatment system is ins-
talled if the quality of the supply/recirculation water so
demands. (Refer to the reference values listed in the
table alongside.)
REFERENCE VALUES
pH
Electrical conductivity
Chlorine ions
Sulphuric acid ions
Total iron
Alkalinity M
Total hardness
Sulphur ions
Ammonia ions
Silicon ions
9
Filters should be installed to eliminate impurities as this
extends the life of the storage cylinder and ensures the cor-
rect functioning of the safety valves.
6-8
less than 200 μS/cm (25°C)
less than 50 ppm
less than 50 ppm
less than 0.3 ppm
less than 50 ppm
less than 35°F
none
none
less than 30 ppm
3.6

Water connections

The BOLLITORE 120 Lt appliance has been designed and built to
be installed on systems producing domestic hot water. Water
fittings have the following specifications:
C
A
B
US
ES
H
DESCRIPTION
A
B
C
D
E
F
G
ES
Heat exchanger inlet
US
Heat exchanger outlet
UAC
Domestic hot water
outlet
EAF
Cold water inlet
We recommend installing, in delivery and on the return line,
sectioning valves.
Connection to the Insieme EVOe 32 V LN boiler is done using the
specific KIT provided that the storage cylinder is beside the boi-
ler, to the right or to the left and away from the wall, at the back,
by at least 200 mm.
Positioning against the wall, at the back, or not next to the boi-
ler requires specific and/or in-wall hydraulic connections.
9
The domestic hot water system ABSOLUTELY MUST HAVE an ex-
pansion tank and a safety valve, and for this purpose the
"Expansion/safety kit" is available as an accessory.
49
D
E
UAC
EAF
G
BOLLITORE 120 Lt
57
mm
77
mm
270
mm
65
mm
265
mm
772
mm
820
mm
3/4" G
Ø
3/4" G
Ø
1/2" G
Ø
1/2" G
Ø

Advertisement

Table of Contents
loading

Table of Contents