Huawei SUN2000-50KTL-M0 User Manual page 89

Hide thumbs Also See for SUN2000-50KTL-M0:
Table of Contents

Advertisement

SUN2000-(50KTL, 60KTL, 65KTL)-M0
User Manual
Parameter
PV module type
Built-in PID
compensation
direction
PID running mode
PID nighttime off-
grid repair
PID daytime off-grid
repair
Issue 06 (2020-07-07)
Description
This parameter is used to set
different types of PV modules and
the shutdown time of the
concentration PV modules. If the
concentration PV modules are
shaded, the power drops drastically
to 0 and the SUN2000 shuts down.
The energy yield would be affected
since it takes too long for the power
to resume and SUN2000 to restart.
The parameter does not need to be
set for crystalline silicon and filmy PV
modules.
The PID effect may result in the
power attenuation of PV modules,
which is mainly caused by the DC
voltage between PV modules and the
ground. Enabling this setting lowers
the DC voltage between PV modules
and the ground by reducing the
impedance on the input side to the
ground.
Specifies the operation mode of the
SUN2000 built-in PID.
Specifies whether to enable the PID
nighttime off-grid repair.
Specifies whether to enable the PID
daytime off-grid repair.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
● If PV module type is set to
Crystalline silicon or Film, the
SUN2000 automatically detects
the power of PV modules when
they are shaded and shuts down
if the power is too low.
● When the concentration PV
modules are used:
– If PV module type is set to
CPV 1, the inverter can
quickly restart in 60 minutes
when the input power of PV
modules drops drastically
due to shading.
– If PV module type is set to
CPV 2, the inverter can
quickly restart in 10 minutes
when the input power of PV
modules drops drastically
due to shading.
This parameter is displayed only if
PV module type is set to
Crystalline silicon.
This parameter is displayed only
for the models that support Built-
in PID repair.
This parameter is displayed only if
PID running mode is set to
Repair.
This parameter is displayed only if
PID running mode is set to
Repair.
81