Table of Contents Q1: If I forget the M2M-710D’s IP, how can I set and operate the M2M-710D by web browser? ..........................3 Q2: Client cannot connect to Server.................. 4 Q3: Server and Client can’t establish Com Port connection..........6 Q4: Why can not the PC of user connect to M2M-710D in VxComm mode? ....
Q1: If I forget the M2M-710D’s IP, how can I set and operate the M2M-710D by web browser? A1: (1) :Please reset system, and IP address will show again. Display IP address (2):Init M2M-710D reference 2.3. Default value of IP address is...
Q2: Client cannot connect to Server. A2: Please follow the following steps to check that the network configuration is correct. Step 1: Check IP of Server and Client is the only. The IP is not the same with the other network device. Step 2: Please confirm the network configurations are correct.
Q3: Server and Client can’t establish Com Port connection. A3: Please follow the steps to check below. Step 1: Confirm client’s name is the same as server permission name list. Step 2: Confirm comport setting of server and client. Server comport setting must the same setting as client.
Q4: Why can not the PC of user connect to M2M- 710D in VxComm mode? A4: Please confirm the mask address. The mask address of PC and M2M-710D must be the same. Like 255.255.0.0 Q5: What kind of version does the VxComm driver support M2M-710D on user’s PC?
Q6: Why can’t M2M-710D connect to VxServer after making sure that the setting of server IP and port are correct and that the server executes VxServer? A06: Please make sure M2M-710D is the same domain with gateway, or change "Boot protocol" into DHCP.