2. During the reboot, Figure 46 displays information about the failing disk. Make
Figure 46. Boot up warning
3. Power off the machine.
4. Continue with the steps described in "Replacing and rebuilding a hard drive

Replacing and rebuilding a hard drive (Models xx3)

Note: Before beginning these procedures, you should have completed one of the
1. Follow the steps in "Replacing a hard disk drive" on page 38 to remove and
2. Reassemble the machine and power on.
After the operating system loads, the RAID application rebuilds the hard disk drive
automatically. During this process, you can use the machine normally. Rebuilding
time varies depending upon the size of the partition, the amount of data and the
system activity during the rebuild.

Accessing the RAID setup menu (Models xx3)

After enabling the RAID function from the BIOS setup menu, you can enter the
RAID setup menu before the Windows OS starts by pressing Ctrl+C or Ctrl+Z on
66
SurePOS 700-723/743/783/784 Hardware Service Guide
note of which drive is the failing disk. Failing drives are indicated with a Broken
status.
(Models xx3)."
two methods on determining the failed hard disk drive.
replace the failing hard disk drive.