Installation Location - Pilz PMCtendo SZ Series Operating Manual

Table of Contents

Advertisement

Installation
5.1

Installation location

The following requirements apply to the installation location:
The installation location must be free of any aggressive substances and any electrically
}
conductive atmosphere
The substructure must be even, free of vibrations and resistant to warpage
}
Sufficient heat dissipation must be ensured; for this purpose, ensure compliance with
}
the permitted surrounding temperature and, as needed, provide additional cooling for
the motor, such as by using a forced ventilation unit
If using a forced ventilation unit, ensure compliance with the minimum clearance of the
}
air intake
Type
SZ.4x
SZ.5x
SZ.7x
SZ.8x
The following graphics show permitted installation positions IM B5, IM V1 and IM V3.
In installation position IM V3, take special care that no fluid from attachments can get into
the motor bearings.
Operating Manual PMCtendo SZ
1002405-EN-04
Forced ventilation unit
FL4
FL5
FL7
FL8
IM B5
Minimum clearance x
20
20
30
30
IM V1
[mm]
Fmin
IM V3
18