Related objects
index
Sub
Object
2C20h
0
VAR
2C21h
0
VAR
2C22h
0
VAR
2C23h
0
VAR
2C24h
0
VAR
2C25h
0
VAR
2C26h
0
VAR
2C27h
0
VAR
2C28h
0
VAR
2C31h
0
VAR
*1 When warning conditions for 2 to 6 are established at the same time, the smallest number is returned.
*2 Once an estimation is complete even after a warning has occurred, the status changes to "Estimation is completed".
Name
Machine diagnostic status
Static friction torque at forward
rotation
Dynamic friction torque at forward
rotation
Static friction torque at reverse
rotation
Dynamic friction torque at reverse
rotation
Oscillation frequency during motor
stop
Vibration level during motor stop
Oscillation frequency during motor
operating
Vibration level during motor operating
Friction estimate status
Data Type
Access
Description
U16
RO
The machine diagnostic status is returned.
[Bit 0 to 3: Friction estimation status at forward
*1*2
rotation]
0: Friction is being estimated. (normal)
1: Estimation is completed. (normal)
2: The motor may have rotated more frequently in
one direction than the other. (warning)
3: The servo motor speed may be slow for friction
estimation. (warning)
4: The change in the servo motor speed may be too
small for friction estimation. (warning)
5: The acceleration/deceleration time constants may
be short for friction estimation. (warning)
6: The operation time may be insufficient. (warning)
[Bit 4 to 7: Friction estimation status at reverse
*1*2
rotation]
0: Friction is being estimated. (normal)
1: Estimation is completed. (normal)
2: The motor may have rotated more frequently in
one direction than the other. (warning)
3: The servo motor speed may be slow for friction
estimation. (warning)
4: The change in the servo motor speed may be too
small for friction estimation. (warning)
5: The acceleration/deceleration time constants may
be short for friction estimation. (warning)
6: The operation time may be insufficient. (warning)
[Bit 8 to 11: Vibration estimation status]
0: Friction is being estimated
1: Estimation is completed.
[Bit 12 to 15: reserved]
I16
RO
Static friction at forward rotation torque is returned.
Unit: 0.1 % (rated torque of 100 %)
I16
RO
Dynamic friction at forward rotation torque at the
rated speed is returned.
Unit: 0.1 % (rated torque of 100 %)
I16
RO
Static friction at reverse rotation torque is returned.
Unit: 0.1 % (rated torque of 100 %)
I16
RO
Dynamic friction at reverse rotation torque at the
rated speed is returned.
Unit: 0.1 % (rated torque of 100 %)
I16
RO
Vibration frequency during stop/servo-lock is
returned.
Unit: [Hz]
I16
RO
Vibration level during stop/servo-lock is returned.
Unit: 0.1 % (rated torque of 100 %)
I16
RO
Vibration frequency during operation is returned.
Unit: [Hz]
I16
RO
Vibration level during operation is returned.
Unit: 0.1 % (rated torque of 100 %)
U16
RO
The progress of friction estimation is returned.
Unit: [%]
4 APPLICABLE FUNCTIONS