■Ready-off command from controller
After the base circuit is turned off with the ready-off command, the servo motor is stopped with the dynamic brake and
electromagnetic brake.
Servo motor speed
Base circuit
MBR
*1
(Electromagnetic
brake interlock)
Ready-on command
(from controller)
*1 ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
3 BASIC FUNCTION
72
3.11 Electromagnetic brake interlock function
(10 ms)
0 r/min
ON
OFF
OFF
ON
OFF
ON
OFF
Dynamic brake
Dynamic brake
+ electromagnetic brake
Electromagnetic brake
Operation delay time of
electromagnetic brake