Made To Order - SMC Networks PF2W7 Series Operation Manual

Digital flow switch (integrated display type)
Hide thumbs Also See for PF2W7 Series:
Table of Contents

Advertisement

Made to Order

●Model Indication and How to Order
Refer to page
10
for details of model indication and how to order.
●Internal circuit and wiring example
When the lead wire with connector designated for PF2W7 is used, the wire colours will apply as shown on
the circuit diagram.
NPN (1 output) + Analogue (1 to 5 V) type
PF2W7
-
-28 - -X560
NPN (1 output) + Analogue (4 to 20 mA) type
PF2W7
-
-29 - -X560
Max. 30 V, 80 mA
Internal voltage drop: 1 V or less
28: Analogue output: 1 to 5 V
Output impedance: 1 kΩ
29: Analogue output: 4 to 20 mA
Load impedance
Power supply voltage 12 V: 300 Ω
Power supply voltage 24 V: 600 Ω
PNP (1 output) + Analogue (1 to 5 V) type
PF2W7
-
-68 - -X560
PNP (1 output) + Analogue (4 to 20 mA) type
PF2W7
-
-69 - -X560
Max. 80 mA
Internal voltage drop: 1.5 V or less
68: Analogue output: 1 to 5 V
Output impedance: 1 kΩ
69: Analogue output: 4 to 20 mA
Load impedance
Power supply voltage 12 V: 300 Ω
Power supply voltage 24 V: 600 Ω