■Setting procedure of initialize mode

<Operation>
Press the
button for 2 seconds or longer during measurement mode.
Selection of display mode
Select the display of instantaneous flow or accumulated flow.
Press the
button to select.
[d_1]: display instantaneous flow
[d_2]: display accumulated flow
The product with unit selection function
Selection of unit selection function
Display unit can only be selected for products with unit selection unction.
Press the
or
Display
Instantaneous flow
[U_1]
L/min
[U_2]
gal(US)/min
: Refer to page
25
for the flow rate when [U_2] is selected.
Selection of output mode (OUT1)
Select the switch output mode required referring to the list of outputs (page 21).
Press the
button to select.
[o10]: Instantaneous output mode
[o11]: Accumulated output mode
[o12]: Accumulated pulse output
mode
Selection of output mode (OUT2)
Select the switch output mode required referring to the list of outputs (page 21).
Press the
button to select.
[o20]: Instantaneous output mode
[o21]: Accumulated output mode
[o22]: Accumulated pulse output
mode
button for selection.
Accumulated flow
L
gal(US)
-23-
Press the
button.
Press the
button.
Press the
button.
Press the
button. (continued)
SI unit only
No.PF※※-OMO0012-D