Using The Web Tools Page Of A Switch Module To Collect Fc Switching Plane Information (Mx510) - Huawei E9000 Troubleshooting Manual

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
4.
----End
4.4.2.5 Using the Web Tools Page of a Switch Module to Collect FC
Switching Plane Information (MX510)
Operation Scenario
Use Web Tools page of a switch module (MX510) to collect information about the
FC switching plane.
This section applies to the CX311, CX911, and CX915.
Prerequisites
Conditions
Data
Table 4-7 Data list
Parameter
IP address
Subnet mask
Default gateway
Issue 20 (2020-09-25)
switch modules are not stacked, log in to each switch module and repeat the
preceding log collection procedure.)
[ftp]mkdir swi2
[ftp]cd swi2
[ftp]mput 2#flash:/logfile/*
[ftp]cd ..
[ftp]quit
221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye
<HUAWEI>
NO TE
– When you use the mput command in the FTP CLI, 2#flash:/ indicates the flash
root directory of the switch module with the stack ID 2. You can obtain the stack
ID and role information by using the display stack command.
– The flash root directory of the master switch module in a stack is flash:/.
– If multiple switch modules are displayed after running the display stack
command, obtain the log file of each switch module in the logfile directory.
View the log file in the FTP directory on the PC.
The connection between the management IP address of the FC switch module
and the server IP address is normal.
You have logged in to the Ethernet switching plane Web Tools page. For
details, see
8.10 Logging In to the Web Tools of the
Copyright © Huawei Technologies Co., Ltd.
Example Value
192.168.1.100
255.255.255.0
0.0.0.0
4 Collecting Information
MX510.
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents