Huawei E9000 Troubleshooting Manual page 85

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Indicator
2 x 100GE optical
port rate
indicators
Issue 20 (2020-09-25)
Status
Off
Steady
green
Off
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
The network port is
not connected.
The data
transmission rate is
100 Gbit/s.
The network port is
not connected.
Diagnosis Procedure
1. Connect the port
to another switch,
optical fiber, and
optical module to
check whether the
original switch
and optical fiber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
N/A
1. Connect the port
to another switch,
optical fiber, and
optical module to
check whether the
original switch
and optical fiber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents