PCE Health and Fitness MiniAir20 Operating Instructions Manual page 40

Table of Contents

Advertisement

Available languages

Available languages

MiniAir20
Air Probe of stainless
steel
Measuring range Flow
Flow accuracy
Measuring range Temp.
Accuracy
Operating temperature
Head dimension
Access opening
Length of probe
Length of cable
Storage temperature
Water Probe
Measuring range Flow
Flow accuracy of Flow
Measuring range Temp.
Accuracy
Operating temperature
Head dimension
Access opening
Length of probe
Length of cable
Storage temperature
40
MiniAir20 Mini
up to 140° ° C Steel
0.3 - 20 m/s
0.5 - 40 m/s
0.5% fs
1.5% rdg
-20 to +140°C
+/- 0.5°C
-30 to +140°C
∅ 22 x 28 mm
35 mm
182 mm
1.5 m
-65 to +150°C
MiniWater20 Micro
0.04 - 5 m/s
0.05 - 10 m/s
2.0% fs
3.0% rdg
0 to +70°C
+/- 0.5°C
-30 to +70°C
∅ 11 x 15 mm
16 mm
165 mm
5 m
-65 to +150°C
MiniAir20 Mini
up to 250° ° C Steel
0.3 - 20 m/s
0.5 - 40 m/s
0.5% fs
1.5% rdg
- - - -
- - - -
-30 to +250°C
Evaluation box up to 65°C
∅ 22 x 28 mm
35 mm
182 mm
2.0 m (250°C)
1.5 m from Box
-65 to +250°C
(Box and Cable
up to 65°C)
MiniWater20 Mini
0.02 - 5 m/s
0.03 - 10 m/s
2.0% fs
1.5% rdg
0 to +70°C
+/- 0.5°C
-30 to +70°C
∅ 22 x 28 mm
35 mm
175 mm
5 m
-65 to +150°C
Schiltknecht Messtechnik AG

Advertisement

Table of Contents
loading

Table of Contents