Cisco ME 1200 Series Hardware Installation Manual page 32

Carrier ethernet access devices
Table of Contents

Advertisement

Grounding the Switch
Figure 3-4
Crimp the fork-type terminals to the 14 or 16 AWG DC power input wires.
Step 2
Connect the wires to the DC input power terminals as shown in Figure 3-4 Make sure to match the polarity
Step 3
(negative to negative, positive to positive) when connecting the wires to the terminal.)
Figure 3-5
Use a ratcheting torque Phillips-head screwdriver to torque the terminal-block screw to 14 in-lb.
Step 4
Do not over-torque the terminal-block screws. The recommended maximum torque is 14 in-lb.
Caution
Grounding the Switch
Follow the grounding procedure instructions and observe these warnings.
Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide
3-4
Stripping the DC Input Power Source Wire
Connecting the DC Input Power Terminal Blocks
Chapter 3
AC and DC Input Power
OL-31962-04