Cisco ME 1200 Series Hardware Installation Manual

Carrier ethernet access devices

Advertisement

Cisco ME 1200 Series Carrier Ethernet Access
Devices Hardware Installation Guide
June 2017
Cisco Systems, Inc.
www.cisco.com
Cisco has more than 200 offices worldwide.
Addresses, phone numbers, and fax numbers
are listed on the Cisco website at
www.cisco.com/go/offices.
Text Part Number: OL-31962-04

Advertisement

Table of Contents
loading

Summary of Contents for Cisco ME 1200 Series

  • Page 1 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide June 2017 Cisco Systems, Inc. www.cisco.com Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco website at www.cisco.com/go/offices. Text Part Number: OL-31962-04...
  • Page 2 OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks.
  • Page 3: Table Of Contents

    Mounting in a Rack Mounting the Switch using 19-inch, 23-inch, and ETSI Brackets Mounting the Switch on a Wall Desktop Mounting Installing and Removing SFP Modules Installing SFP Modules Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 4 2-11 Initial Configuration 2-12 Scenario 1 - Zero Touch Provisioning 2-12 Scenario 2 - Accessing Cisco ME1200 NID Through ME3600 UPE NID Controller Mode 2-12 Installing an AC Power Cord Retainer Clip C H A P T E R Installing an AC Power Cord...
  • Page 5: Audience

    Preface Audience This guide is for the person installing the Cisco ME 1200 Series Carrier Ethernet Access Devices, also known as Cisco ME 1200 NID. Purpose This guide describes the hardware features of the Cisco ME 1200 NID. It describes the physical and performance characteristics of the switch, explains how to install it, and provides troubleshooting information.
  • Page 6: Related Publications

    Subscribe to What’s New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 7: Setting Up The Switch

    Switch Models The Cisco ME1200 NID switches have fixed AC and DC power options. Each switch has 4 1GE SFP (Small Form factor Pluggable) ports and two RJ-45 copper Ethernet ports. All the variants support power redundancy using an external AC-DC power adapter.
  • Page 8: Front Panel

    The console port is used in display-only mode to output debug information. Console operation is not supported. The serial port’s configuration requirements are as follows: Default Baud rate—115,200 bps • Parity—None • Stop bit—One • Data bits—8 • Flow control—none • Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 9: 10/100/1000 Gigabit Ethernet Ports

    10/100/1000 Ethernet port, regardless of the type of device on the other end of the connection. SFP Modules The SFPs listed in Table 1-2 are supported in Cisco ME1200 NID. Please contact Cisco for details on support of additional Cisco optical modules. Table 1-2...
  • Page 10: Leds

    0 LEDs Figure 1-3 Cisco ME1200-4S-A and ME1200-4S-D Switch LEDs SYS (system) LED Port LED (SFP) Port LED (RJ-45)     Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 11: System Led

    RJ-45 /SFP activity link on 1Gbps Right side LED Amber RJ-45 link on 100Mbps/10Mbps SFP link on 100Mbps Blinking Amber RJ-45 activity link on 10/100Mbps SFP activity link on 100Mbps Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 12: Rear Panel

    Management Option 1 In this model, there will be a Cisco UPE and a Cisco Edge device. The NID will be downstream device, on the Cisco UPE. A UPE NID Controller software subsystem on the ME3600 UPE will be used to manage the NID.
  • Page 13: Management Option 3

    Management Option 3 In this model, another Cisco edge router like ASR -9K directly connects to the NID. There is no UPE, and there is unlikely to be a UPE NID Controller subsystem in the ASR 9K. Such customers may use PRIME or a 3rd party NMS.
  • Page 14 Chapter 1 Product Overview Management Options Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 15: Warnings

    Ethernet cables must be shielded and grounded at both ends when they are used in a non-central office Note environment. Do not work on the system or connect or disconnect cables during periods of lightning activity. Warning Statement 1001 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 16 Statement 1046 No user-serviceable parts inside. Do not open. Statement 1073 Warning Installation of the equipment must comply with local and national electrical codes. Statement Warning 1074 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 17: Installation Guidelines

    If the switch is installed in a closed or multi-rack assembly, the temperature around it might be greater than Note normal room temperature. Before you connect the switch to a power source, note the power consumption specifications in • Appendix A, "Technical Specifications" Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 18: Verifying Switch Operation

    The bracket orientation and the brackets that you use depend on whether you are attaching the brackets for a 19-inch, 23-inch, ETSI rack, or Wall mount. Figure 2-1 shows the types of mounting brackets. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 19 For 19-inch brackets, use part number RCKMNT-ME12-19IN • For 23-inch brackets, use part number RCKMNT-ME12-23IN • For ETSI-racks brackets, use part number RCKMNT-ME12-ETSI • For Wall mount, use part number RCKMNT-ME12-WALL • Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 20: Mounting In A Rack

    After the brackets are attached on the switch, use the four supplied number-12 Phillips machine screws to securely attach the brackets to the rack. See Figure 2-3 for standard rack-mounting using the 19-inch, 23-inch, and ETSI brackets. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 21: Mounting The Switch Using 19-Inch, 23-Inch, And Etsi Brackets

    Phillips flat-head screws 2 Cable guide and screw For Cable manager, use part number ME1200-CAB-MNGT • Mounting the Switch on a Wall The wall mounting screws are user-supplied. Note Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 22: Desktop Mounting

    Power on the switch. See the “Verifying Switch Operation” section on page 2-4 • Connect to the console port, and run the initial configuration. See the Cisco NID Controller Guide for • instructions. Connect to the front-panel ports. See the “Connecting to the 10/100/1000 Ports” and the“Connecting to •...
  • Page 23: Installing And Removing Sfp Modules

    Set the device on a flat surface near a power source, making sure there are at least two inches of space on all Step 2 sides for proper air flow. Installing and Removing SFP Modules Installing SFP Modules Figure 2-7 shows a SFP module that has a bale-clasp latch. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 24 Note fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP module ports and cables from contamination and ambient light. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide 2-10 OL-31962-04...
  • Page 25 Let the ports auto-negotiate both speed and duplex. • Set the port speed and duplex parameters on both ends of the connection. • Follow these steps to connect to 10BASE-T, 100BASE-TX, or 1000-BASE-T devices: Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide 2-11 OL-31962-04...
  • Page 26 Scenario 1 - Zero Touch Provisioning Refer to the ZTP section in the Cisco NID Controller Guide. Scenario 2 - Accessing Cisco ME1200 NID Through ME3600 UPE NID Controller Mode All Cisco ME1200 NID will have 192.0.2.1 as factory installed default IP address.
  • Page 27 192.0.2.1 static Step 1 to Step 4 are performed so that for the first time, we can access Cisco ME1200 NID through the UPE Note NID Controller ME3600 with the default factory IP address Cisco ME1200 NID comes with (192.0.2.1). The above steps 1 to 4 are mandatory and sufficient to establish the initial connectivity between the UPE NID Controller and Cisco ME1200 NID.
  • Page 28 Physical Port VLAN TFTP Server Type 192.0.2.1 static 7.6.15.59 static Now, using ‘controller nid 1/2’ the Cisco ME1200 NID can be accessed on a different SVI. Step 12 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide 2-14 OL-31962-04...
  • Page 29 C H A P T E R AC and DC Input Power This chapter provides the installation instructions for the AC and DC input power for the Cisco ME1200 switches Installing an AC Power Cord Retainer Clip, page 3-1 •...
  • Page 30 Installing an AC-to-DC Power Adapter The DC jack’s central post is 2.5mm wide and conforms to the DC receptacle (2.5mm). Connect the DC jack cable between ME1200-4S-A/D and adapter Step 1 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 31 Using a wire-stripping tool, strip each of the wires coming from the DC input power source to 0.350 inch (8.9 Step 1 mm) ± 0.02 inch (0.5 mm). Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 32 Step 4 Do not over-torque the terminal-block screws. The recommended maximum torque is 14 in-lb. Caution Grounding the Switch Follow the grounding procedure instructions and observe these warnings. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 33 Slide the open end of the ground lug over the exposed area of the wire. Step 3 Crimp the ground lug to the wire (see Figure 3-7). Step 4 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 34 Use a ratcheting torque Phillips-head screwdriver to torque the ground-lug screws to 32 in-lb. Step 6 Connect the other end of the grounding wire to an appropriate grounding point at your site or to the rack. Step 7 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 35 The LEDs on the front panel provide troubleshooting information about the switch. They show power-on self-test (POST) failures, port-connectivity problems, and overall switch performance. You can also get statistics from the CLI on the UPE NID Controller. See the Cisco NID Controller guide on Cisco.com for more information.
  • Page 36 Finding the Switch Serial Number If you contact Cisco Technical Assistance, you need to know the serial number of your switch. Use the following figure to locate the serial number location. You can also use the show inventory user EXEC command to get the serial number.
  • Page 37 Typical:8.58 W (4 SFPs with 1000BASE-SX, 100% traffic). Minimum: 5.54 W (no cables or SFP modules installed). Power rating: 120 V (0.018 KVA), 230 V (0.023 KVA). Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 38 Input voltage range and frequency 100 to 240 VAC ± 10% (auto-ranging), 50 to 60 Hz Input current 0.9A MAX Note For AC input, a 3.15A fuse is recommended Maximum output ratings 12 V @ 3.33 A Total input BTU 655BTUs per hour Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 39 The 10/100/1000 Ethernet ports use standard RJ-45 connectors and Ethernet pin-outs. Figure B-1 10/100/1000 Port Pin-out SFP Module Connectors Figure B-2, Figure B-3, and Figure B-4 show the SFP module connectors. Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 40 Copper 1000BASE-T SFP transceivers use standard four twisted-pair, Category 5 (or greater) cable at lengths up to 328 feet (100meters). Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 41 1000BASE-ZX 1550 G.652² ─ 43.4 to 62 miles (GLC-ZX-SM) (70 to 100 km)^4 CWDM 1470, 1490, G.652² ─ 62 miles (100 km) 1510, 1530, 1550, 1570, 1590, 1610 Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 42 SFP Module Cabling Cable Pin-outs Figure B-5 Two Twisted-Pair Straight-Through Cable Schematic Figure B-6 Two Twisted-Pair Crossover Cable Schematic Figure B-7 Four Twisted-Pair Straight-Through Cable Schematic for 1000 Base-T Ports Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...
  • Page 43 PC. You need to provide an RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter from Cisco. For console port and adapter pin-out information, see Table B-2 and Table B-3.
  • Page 44 ACS-DSBUASYN=) containing this adapter from Cisco. Table B-3 Console Port Signaling Using a DB-25 Adapter Switch RJ-45-to-DB-25 Console Console Port Terminal Device (DTE) Adapter Signal DB-9 Pin Signal Cisco ME 1200 Series Carrier Ethernet Access Devices Hardware Installation Guide OL-31962-04...

Table of Contents