Tab.6
Heating mode: outdoor air temperature +2 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measurement type Unit
Heat output
kW
Coefficient of Per­
formance (COP)
Absorbed electri­
kWe
cal power
Tab.7
Cooling mode: outdoor air temperature +35 °C, water temperature at the outlet +18 °C. Performances in accordance
with EN 14511-2.
Measurement type Unit
Cooling output
kW
Energy efficiency
ratio (EER)
Absorbed electri­
kWe
cal power
Tab.8
Common specifications
Measurement type Unit
Power voltage of
V
the outdoor unit
Start-up amperage A
Maximal amper­
A
age
Refrigerant fluid
kg
R410A
R410A refriger­
tCO
2
ant
(1)
Refrigerant con­
inch
nection (Liquid -
Gas)
Max. pre-charged
m
length
(1) The quantity of refrigerant in CO
Global-Warming Potential (GWP) of R410A gas is 2088.
Tab.9
Indoor module
Indoor module
Unit
Weight (empty)
kg
Tab.10
Indoor module
Indoor module
Unit
Weight (empty)
kg
7748711 - v03 - 08062020
AWHP 4.5
AWHP 6
MR
MR-3
3.47
3.74
3.97
3.37
0.88
1.11
AWHP 4.5
AWHP 6
MR
MR-3
3.80
4.69
4.28
4.09
0.89
1.15
AWHP 4.5
AWHP 6
MR
MR-3
230
230
5
5
12
13
1.3
1.4
e
2.714
2.923
1/4 - 1/2
1/4 - 1/2
7
10
equivalent is calculated using the following formula: quantity (in kg) of refrigerant x GWP / 1000. The
2
MIV-S 4-8/EM
35.5
MIV-S
MIV-S
11-16/EM
11-16/EMI
35.5
36.7
AWHP 8
AWHP 11
MR-2
MR-2
6.8
10.19
3.3
3.20
2.06
3.19
AWHP 8
AWHP 11
MR-2
MR-2
7.90
11.16
3.99
4.75
2.00
2.35
AWHP 8
AWHP 11
MR-2
MR-2
230
230
5
5
17
29.5
3.2
4.6
6.680
9.603
3/8 - 5/8
3/8 - 5/8
10
10
3.2.3

Heat pump weight

MIV-S 4-8/EMI
36.7
MIV-S
11-16/ET
35.5
3 Technical specifications
AWHP 11
AWHP 16
TR-2
MR-2
10.19
12.90
3.20
3.27
3.19
3.94
AWHP 11
AWHP 16
TR-2
MR-2
11.16
14.46
4.75
3.96
2.35
3.65
AWHP 11
AWHP 16
TR-2
MR-2
400
230
3
6
13
29.5
4.6
4.6
9.603
9.603
3/8 - 5/8
3/8 - 5/8
10
10
MIV-S 4-8/H
MIV-S 4-8/HI
36.1
38.2
MIV-S
MIV-S
11-16/ETI
11-16/H
36.7
36.1
AWHP MIV-S
AWHP 16
TR-2
12.90
3.27
3.94
AWHP 16
TR-2
14.46
3.96
3.65
AWHP 16
TR-2
400
3
13
4.6
9.603
3/8 - 5/8
10
MIV-S
11-16/HI
38.2
13